          Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
          Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
          SC-4 security expansion module
          SM-602 programmable safety controller

          As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

          (1) Redundancy

          (2) Difference

          (3) Self-detection


             How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

          SC-4 security expansion module

          841056c.png

          · Is a safety relay output expansion module.

          · Receive the on-site safety switch signal, and expand it into 4 NO (normally open) safety output contacts and 2 NC (normally closed) auxiliary output contacts. 
          · Two auxiliary contacts can be used for output status indication and fault feedback respectively.

          Product selection     0523ce09f27183840accf49d6c9b5a4.png

          product name

          model

          Safety input

          Safe output

          order number

          SC-4

          24V DC

          Safety switch, contact switch

          4NO+2NC

          LHS
          explain

          Safety switch, contact switch


          safety performance

          ·Performance level (PL): PLE

          ·Safety category (cat.): cat.4.

          ·Task time (TM): 20 years.

          ·Diagnostic coverage (DC/DC AVG): 99%

          ·Safety integrity level (SIL): SIL3

          ·Hardware fault margin (HFT): 1

          ·Safety Failure Score (SFF): 99%

          ·PFHD: 1.78e-9/h

          ·Stop category: 0           

          Comply with the standard EN ISO13849

          Comply with the standard EN ISO13849

          Comply with the standard EN ISO13849

          Comply with the standard EN ISO13849

          Comply with standards IEC61508, IEC62061.

          Comply with standards IEC61508, IEC62061.

          Comply with standards IEC61508, IEC62061.

          Comply with standards IEC61508, IEC62061.

          Comply with standard EN 60204-1.


          Main technical parameters

          Power supply characteristics

          ·Power supply voltage: 24VDC

          ·Voltage range: -15%~+10%

          ·Current loss: ≤70mA(24VDC)

          Input characteristics

          ·Input current: ≤70mA(24VDC)

          ·Conductor resistance: ≤15Ω

          ·Input equipment: safety switch, contact switch.

          output characteristic

          ·Number of contacts: 4NO+2NC

                 Safety outputs: 13, 14, 23, 24, 33, 34, 43, 44.

                 Auxiliary outputs: 11, 12 (status)

                 Y1, Y2 (feedback)

          ·Contact material: AgSnO2+0.2 μm Au.

          ·Contact type: forced guidance

          ·Contact fuse protection: 10A gL/gG, NEOZED (normally open contact)

                 6A gL/gG, NEOZED (normally closed contact)

          ·Switching capacity (en 60947-5-1): AC-15, 5a/230v; DC-13, 5A/24V

          ·Mechanical life: more than 107 times

          Time characteristic

          ·Suction buffer time: ≤30ms

          ·Release buffer time: ≤20ms

          ·Recovery time: ≤1000ms

          ·Short interruption of power supply: 20ms


          Environmental characteristic parameters

          ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

          ·Vibration frequency: 10Hz~55Hz

          ·Vibration amplitude: 0.35mm

          ·Operating temperature: -20℃~+60℃

          ·Storage temperature: -40℃~+85℃

          ·Relative humidity: 10%~90%

          ·Electrical clearance and creepage distance: in accordance with EN60947-1.

          ·Overvoltage grade: Ⅲ

          ·Pollution level: 2

          ·Altitude: ≤2000m

          ·Rated isolation voltage: 250VAC.

          ·Rated impulse voltage: 6000V(1.2/50us)

          ·Insulation strength: 1500VAC for 1min.

          841056c.png


          Functional application parameters

          functional block diagram

          Typical application

          圖片2.png

          典型應(yīng)用圖.png


          Overall dimensions (depth× height× width):

          Overall dimensions (depth× height× width):114.5mm×99.0mm×22.5mm

          Net weight of product200g

          外形尺寸圖.png


          Wiring diagram

          Power supply/input loop

          Switch input

          電路圖1.png

          Output loop

          電路圖2.png

          feedback loop

          電路圖3.png


          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 乱伦日屄| 无码中文字幕DⅤD免费放| 中文字幕国产精品资源| 夜夜精品浪潮av一区二区三区| 天天燥日日燥| 久久精品国产亚洲AV蜜臀色欲| 国产在线欧美一区二区| 欧美在线观看a| 亚洲高清国产拍精品网络战| 亚洲中文无码AV在线| 色婷婷精品大在线视频| 久久综合给合久久狠狠狠| 91久久精品视频| 欧美亚洲日韩精品一卡二卡| 岛国av黄片在线播放| 精品无码一区二区三区电影| 无码毛片aaa在线| 精品无码老熟妇magnet| 美日韩无码| 淮南市| 无码熟妇人妻AV在线影片最多| 亚洲熟女食品| 国产漂亮白嫩美女在线观看| 色综合AV综合无码综合网站| 精品少妇牲交视频大全| 日韩一卡二卡三卡四卡五卡| 国产AV中文字幕| 国产免费又黄又爽又色毛| 夜夜性日日交xxx性视频| 国内大量揄拍人妻在线视频| 亚洲制服丝袜一区二区三区| 亚洲国产精品久久久天堂麻豆宅男 | 人人久精品综合777人人精品综合777| 亚洲激情五月天| 强开少妇嫩苞又嫩又紧九色| www.亚洲成年人网站| 中文字幕av无码一区二区三区| 日本成人免费网站| 国内精品久久久久电影院| 日韩精品亚洲精品第一页| 99xxxx激情综合网|