          Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
          Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
          SM-602 programmable safety controller

          As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

          (1) Redundancy

          (2) Difference

          (3) Self-detection


             How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


          SM-602 programmable safety controller

          1720164449995785.png

          Is a configurable safety controller, which supports the input of various safety product components.

          Maximum support for 6 sets of dual-loop inputs.

          2-way safety relay output

          4-channel semiconductor safety output, expandable output module

          Modbus protocol communicationInput and output fault indicator light

          Safety certification: PL e, Cat: 4


          Product selection

          product name

          Type number

          Safe input

          Output

          Brand

          Safety controller

          SM-602

          6CH

          2NO+4SO

          LHS

          explain

          Up to 6 sets of dual-channel safety products can be entered.

          Safety grating, emergency stop, safety door lock, reset, etc.

          Official website programming software download connection: http://lhsafety.com.cn/showinfo-257-118-0.html








          safety performance

          ? Performance level (PL): PL e

          ? Security category (Cat.): Cat.4

          ? Mission time (TM): 20 years

          ? Diagnostic coverage (DC/DC avg): 99%

          ? Safety Integrity Level (SIL): SIL3

          ? Hardware Fault Margin (HFT): 1

          ? Safe Failure Score (SFF): 99%

          ? Probability of dangerous failure (PFH d): 1.78E-9/h

          ? Stop Category: 0/1

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Complies with standard EN 60204-1


          Main technical parameters

          Power supply 

          characteristics

          ·Power supply voltage: 24VDC

          ·Voltage range: 20~30VDC

          ·Current loss: ≤110mA(24VDC)

          Input characteristics

          ·Input current: ≤10mA(24VDC)

          ·Conductor resistance: ≤15Ω

          ·Input equipment: emergency stop button, safety door, two-hand button safety light curtain, magnetic safety switch, etc.

          ·Input channel: 6

          Relay output 

          characteristics

          ·Number of contacts: 2NO (safety output)

          ·Contact material: AgSnO2

          ·Contact fuse protection: 10A is fast, 6A is slow.

          ·Switching capacity: 5A/230VAC;; 5A/24VDC

          Semiconductor output characteristics

          ·Number of contacts: 4SO (safety output)

          ·Contact fuse protection: 10A is fast, 6A is slow.

          ·Switching capacity: 2A/24VDC

          Time characteristic

          ·Suction buffer time: ≤100ms

          ·Release buffer time: ≤30ms

          ·Recovery time:

                   Emergency stop operation: ≤30ms

                   Power failure: ≤1000ms

          ·Recovery time:

                   Emergency stop operation: ≤30ms

                   Power failure: ≤100ms

          ·Short-term power interruption: 20ms

          Communication 

          characteristics

          ·Baud rate: 38.4kbps (fixed)

          ·Communication length: ≤1000m

          ·Networking capacity: ≤10 units


          Environmental characteristic parameters

          ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

          ·Vibration frequency: 10Hz~55Hz

          ·Vibration amplitude: 0.35mm

          ·Service temperature: -20℃~+60℃

          ·Storage temperature: -40℃~+85℃

          ·Relative humidity: 10%~90%

          ·Overvoltage grade: Ⅲ

          ·Pollution level: 2

          ·Altitude: ≤2000m

          ·Rated isolation voltage: 250VAC.

          ·Rated impulse voltage: 6000V(1.2/50us)

          ·Insulation strength: 1500VAC, 1min.

          ·Electrical clearance and creepage distance: in accordance with EN60947-1.

          1666333314320610.png


          Functional application parameters

          functional block diagram

          Typical application

          圖片3.png

          圖片4.png


          Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

          Input element: CH4 (emergency stop button); CH5 (emergency stop button); CH6 (reset button)

          Control logic: CH1&CH2CH4&CH5

          Reset mode: manual reset output delay: 0s.

          Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


          Wiring diagram

          Power Supply 

          1.png

          correspondence

          1655948458157829.png

          input

          3.png4.png5.png
          6.png7.png
          9.png10.png

          reset

          11.png12.png

          feedback

          13.png14.png

          output

          15.png16.png17.png


          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 午夜av高清在线观看| 俺也去网| 国产suv精品一区二区33| 人妻斩0930无码视频| 青青青草国产| 亚洲色图自拍| 亚洲午夜精品国产电影在线观看| 欧美日韩一本的免费高清视频| 手机免费A?V网站| 精品人妻无码区二区三区| 亚洲国产成人久久综合人| 欧美最猛性xxxxx免费| 国产乱人伦AⅤ在线麻豆A| 久久精品国产再热青青青| 热久久视久久精品2019| 加勒比无码一区二区三区| 久久久久波多野结衣高潮| 国产va视频| 国产高清自产拍AV在线| 午夜亚洲av永久无码精品| 中文字幕一区二区三区在线毛片| 成人精品视频一区二区三区| 97人人人| 无码人妻久久一区二区三区免费丨 | 国产一区二区三区不卡AV| 国内精品大秀视频日韩精品| 国产成人啪精品午夜网站| a片网| av不卡在线| 东京热av无码一区二区| 亚洲成在人网站av天堂| 亚洲精品中文字幕码专区| 91亚洲国产三上悠亚在线播放| P尤物久久99国产综合精品| 欧美成人免费全部观看国产| 天天躁日日躁狠狠躁人妻| www欧美在线观看| 欧美丝袜高跟鞋一区二区| 欧美成人精品第一区| 国内自拍视频在线一区| 国产无码VA|