          NJ500 series obstacle avoidance laser scanner


          1726194842215581.png

          ·It is a single-line lidar based on dTOF ranging principle.

          ·It has the advantages of small size, simple use and high cost performance.

          ·Suitable for navigation, obstacle avoidance and diversification of regional monitoring scenes.


          Product specification

          product model

          Maximum detection range

          Detection accuracy

          Scanning angle

          output form

          NJ501-1570CP

          15m@70% reflectivity

          ±4mm@1sigma

          270°

          PNP

          NJ501-1570CN

          15m@70% reflectivity

          ±4mm@1sigma

          270°

          NPN

          NJ501-2570CP

          25m@70% reflectivity

          ±4mm@1sigma

          270°

          PNP

          NJ501-2570CN

          25m@70% reflectivity

          ±4mm@1sigma

          270°

          NPN

          NJ501-2570HP

          25m@70% reflectivity

          ±4mm@1sigma

          270°

          PNP

          NJ501-2570HN

          25m@70% reflectivity

          ±4mm@1sigma

          270°

          NPN

          NJ501-3570HP

          35m@70% reflectivity

          ±4mm@1sigma

          270°

          PNP

          NJ501-3570HN

          35m@70% reflectivity

          ±4mm@1sigma

          270°

          NPN

          NJ501-4070HP

          40m@70% reflectivity

          ±4mm@1sigma

          270°

          PNP

          NJ501-4070HN

          40m@70% reflectivity

          ±4mm@1sigma

          270°

          NPN

          Installation mode

          Horizontal installation mode (SZ), vertical installation mode (CZ) and protective cover installation mode (FZ)

          Power cord

          The standard is 1m, and the length of 5m can be selected.

          Programming line

          Standard gift

          explain

          The difference between NJ500 obstacle avoidance scanner C series and H series lies in:

          1. The angular resolution of C series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40hz is supported; The angular resolution of H series is: 0.3°@30HZ by default, and 0.3 @ 20/25/30hz/40/50hz is supported; In contrast, the H series has an extra 50Hz motor speed.

          2. The response time of H series can be faster by scanning the same data.

          3. At the same time, the display refresh rate of objects around H series is higher.


          Laser scanner main body

           Power cordProgramming line

          1726194842215581.png

           

          1667524189836556.png


          96160.png


          technical parameter

          Angular resolution

          Measuring parameter

          Ranging radius

          15m@70% reflectivity /25m@70% reflectivity /35m@70% reflectivity /40m@70% reflectivity

          Scanning range angle

          270°

          Angular resolution

          The default value is 0.3°@30HZ, and it supports 0.3 @ 20/25/30hz/40Hz/50Hz (NJ 500 obstacle avoidance scanner C series supports 40hz at the highest and H series supports 50hz at the highest).

          Distance deviation

          ±2cm(Typical) ①

          repeatability

          ±4mm@1sigma②

          Scanning plane angle

          Pitch 0.5; Roll 0.5

          Electrical/mechanical parameters

          operating voltage

          DC9~28V

          Power-on start time

          Typical value 10s

          power consumption

          < 2w (no load at output)

          output

          PNP/NPN available (default PNP)

          outline dimension

          52mm×52mm×70mm

          Cable length

          standard 1m

          ambient temperature

          Work:-10℃ ~ 50℃ (no frost and fog in the window); Storage:-40℃ ~ 70℃

          ambient humidity

          Work: 35% RH ~ 85% RH; Storage: 35% RH ~ 95% RH

          Anti-light interference

          80000Lux

          resist the impact

          Acceleration 10g;; Pulse duration: 16ms

          Collision times: three axes, each axis is 1000 10 times.

          Vibration resistance

          Frequency 10 Hz ~ 55 Hz; Amplitude: 0.35±0.05mm

          Scanning times: 20 times for each of XYZ three axes.

          the protection grades

          IP65

          Electromagnetic compatibility

          (EMC)

          EMI

          EN61326-1:2013

          EN55011:2009+A1:2010

          EMS

          EN61326-1:2013

          EN61000-4-2:2009

          EN61000-4-3:2006+A1:2009+A2:2010

          EN61000-4-4:2004+A1:2010

          EN61000-4-6:2014

          EN61000-4-8:2010

          Configurable function

          Sector configuration

          Users can configure YB's protection zone into the required shape through configuration software.

          Response time

          67ms(2 scans) ~ ~536ms(16 scans), and the default is 67ms.

          Zone group switching

          Four groups of external input signals (INPUT1, INPUT2, INPUT3, INPUT4) realize the switching of 16 regional groups.

          Note:

          1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

          2. 10% black velvet 600mm position measurement statistics.


          Schematic diagram of working principle and protection area configuration

          Schematic diagram of protection area 1

          Schematic diagram of protection area 2

          1726196477634861.png1726196505964341.png

          sign

          meaning

          describe

          1

          Protected area 1

          OUTPUT1 enters the OFF state when an obstacle is detected.

          2

          Protected area 2

          OUTPUT2 enters the OFF state when an obstacle is detected.

          3

          Protected area 3

          OUTPUT3 enters the OFF state when an obstacle is detected.

          Note:

          1. The measurement error of materials with different reflectivity is controlled within 2cm (typical value). The ex-factory test method: Three kinds of test pieces (black flannel, white paper and reflective sticker) are placed at different angles and the same distance (59cm) on the whole machine inspection automation fixture. The deviation between the central value of each material and the real distance is within 2 cm, and the maximum difference between the three materials is within 2 cm.

          2. 10% black velvet 600mm position measurement statistics.



          Schematic diagram of working principle and protection area configuration

          Schematic diagram of protection area 1

          Schematic diagram of protection area 2

          1726196477634861.png1726196505964341.png

          sign

          meaning

          describe

          1

          Protected area 1

          OUTPUT1 enters the OFF state when an obstacle is detected.

          2

          Protected area 2

          OUTPUT2 enters the OFF state when an obstacle is detected.

          3

          Protected area 3

          OUTPUT3 enters the OFF state when an obstacle is detected.


          Indicator light status

          1726196717891121.png

          OK: After power-on, the trouble-free OK light is always on, and the trouble-free OK light flashes.

          INPUT(1~4): lit when the input is ON, and turned OFF when the input is OFF.

          OUTPUT(1~3): lights when there is no obstacle, and turns off when there is an obstacle.

          Note: When the equipment is just powered on, all the indicator lights will enter the running water state, and the OK light will go out for 10 seconds, indicating that the equipment is starting and is in a normal state.


          Cable interface

          The configuration cable is a standard USB Type-C data cable (optional).

          See the figure below for the cable structure, and the standard cable length is 1m.

          1726196848500139.png

          colour

          signal

          describe

          blue

          0V

          working power supply

          palm

          24V

          Yellow/green

          PE

          Red/blue

          COM

          The common terminal of the regional group switching signal input, when the input signal is PNP logic, COM is connected to 0V; When the input signal is NPN logic, COM is connected to 24V.

          powder

          INPUT1

          Regional group selection signal, which can switch between regional groups through the changes of input signals of INPUT1, INPUT2, INPUT3 and INPUT4.

          green

          INPUT2

          ash

          INPUT3

          red

          INPUT4

          black

          OUTPUT1

          Three independent PNP(NPN) outputs;

          PNP transistor output; In the ON state, the load current is ≤100mA and the output voltage is ≥ VCC-2v; In the OFF state, the leakage current is ≤1mA, and the residual voltage is ≤ 1V (excluding the influence of wire extension).

          When the NPN transistor outputs, the load current is ≤100mA and the output voltage is ≤2V in the ON state; In the OFF state, the leakage current is ≤1mA and the residual voltage is ≤2V (excluding the influence of wire extension).

          The protectiON area is on when there is no object; In the OFF state when there is an object.

          white

          OUTPUT2

          purple

          OUTPUT3

          Ash/powder

          OK

          Independent PNP(NPN) output, the fault state output is OFF, and it is ON when there is no fault.


          Product dimension diagram

          1726197437255476.png


          Scanning range

          1726197507946675.png


          Installation mode

          Horizontal installation mode

          1726197845421148.png      1726197877884073.png

          Vertical installation mode

          1726197965435752.png1726198002661049.png

          Installation mode of protective cover

          1726198028335499.png1726198054130018.png
          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 国产熟女视频| 野花香高清在线观看视频播放免费| 日韩精品亚洲一区中文字幕 | 国产免费av网站| 亚洲av永久无码精品水牛影视| 日韩最新中文字幕| 久久人妻少妇偷人精品综合桃色| 亚洲国产欧美在线人成app| 欧美交A欧美精品喷水| 国产av天堂亚洲国产av下载| 91探花国产综合在线精品| 欧美色A?V| 热99re99首页精品亚洲五月天| 欧美人与禽交片mp4| 欧美精品影院| 国产精品福利视频一区| 成人亚洲视频| 亚洲伊人色| 亚洲国产精品国语在线| 老司机av到货凹凸| 女厕偷窥一区二区三区| 熟妇人妻无码中文字幕老熟妇| 国产精品未满十八禁止观看| 亚洲都市激情| 伊人久久大香线蕉综合色狠狠 | 国产乱精品一区二区三区| 探花AV| 免费人成视频19674不收费| 欧美操日韩| 91精品国产福利在线导航| av男人的天堂在线观看国产| 少妇极品熟妇人妻| 特级无码毛片免费视频尤物| 一色道久久88加勒比一| 漂亮人妻被中出中文字幕久久| 国产在线拍偷自揄观看视频网站| 美女mm131爽爽爽午夜| 好想被狂躁无码视频在线字幕| 亚洲精品97福利在线| 亚洲一区二区三区含羞草| 国产VA在线视频观看|